GB/Z 43963-2024
ActiveGuidance for determination of clearances, creepage distances and requirements for solid insulation for equipment with a rated voltage above 1 000 V AC and 1 500 V DC, and up to 2 000 V AC and 3 000 V DC
确定额定电压在交流1000V以上至2000V,直流1500V以上至3000V间设备的电气间隙、爬电距离的数值以及对固体绝缘要求的指南
Application Summary AI generated
This standard provides guidance for calculating minimum electrical clearances and creepage distances, and specifies requirements for solid insulation in equipment operating within a voltage range of 1,000 V to 2,000 V AC and 1,500 V to 3,000 V DC. It is applied by engineers designing high-voltage electrical equipment, such as switchgear, transformers, and power converters, to ensure safe insulation coordination and prevent electrical breakdown. The standard is used in product development, testing, and certification contexts to meet safety regulations for industrial and utility-grade electrical installations.
Related Standards
GB/T 19443-2004
Insulators for overhead lines with a nominal voltage above 1000V--Ceramic or glass insulator units for d.c. systems--Difinitions,test methods and acceptance criteria
GB/T 4585-2004
Artificial pollution tests on high-voltage insulators to be used on a.c. systems
GB/Z 23756.1-2009
Evaluation of electrical endurance of electrical insulation systems - Part 1: General considerations and evaluation procedures based on normal distributions
GB/Z 16935.2-2013
Insulation coordination for equipment within low-voltage systems―Part 2-1: Application guide-Explanation of the application of the IEC 60664 series, dimensioning example and dielectric testing
GB/Z 16935.6-2016
Insulation coordination for equipment within low-voltage systems—Part 2-2: Interface considerations—Application guide
GB/Z 37754-2019
Guidance on clearances and creepage distances in particular for distances equal to or less than 2mm—Test results of research on influencing parameters
GB/T 775.2-2003
Test method for insulators--Part2: Electrical test methods
GB/T 1001.1-2003
Insulators for overhead lines with a nominal voltage above 1000V--Part 1: Ceramic or glass insulator units for a.c.systems--Definitions,test methods and acceptance criteria
Transparency note: The application summary and key sentences on this page were automatically generated by AI from the standard's original text. This content has not been human-verified and should not be used for compliance or regulatory purposes. Always refer to the official standard document from the issuing authority.