GB/T 35680-2017

Active

Measuring method for electromagnetic parameters of liquid materials at microwave frequencies using an open-ended coaxial probe

液体材料微波频段使用开口同轴探头的电磁参数测量方法

Standard Type
GBT
ICS
17.240
CCS
N05
Status
Active
Issue Date
2017-12-29
Implementation
2018-07-01
Centralized Committee
中国电器工业协会
Issuing Authority
中华人民共和国国家质量监督检验检疫总局、中国国家标准化管理委员会

Application Summary AI generated

This standard specifies a measurement method for determining the complex permittivity and permeability of liquid materials at microwave frequencies using an open-ended coaxial probe. It is applied in industries such as chemical engineering, food processing, and materials science for quality control and research, specifically for testing the electromagnetic properties of liquids like oils, solvents, and biological fluids. The method is used in laboratory and production environments where non-destructive, broadband characterization of liquid samples is required.

Related Standards

GB/T 12162.2-2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy--Part 2:Dosimetry for radiation protection over the energy ranges 8keV to 1.3 MeV and 4MeV to 9MeV GB/T 12162.3-2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy--Part 3:Calibration of area and personal dosemeters and the measurement of their response as a function of en GB/T 7165.1-2005 Equipment for continuous monitoring of radioactivity in gaseous effluents Part1:General requirements GB/Z 28820.4-2022 Long-term radiation ageing in polymers—Part 4: Effects of different temperatures and dose rates under radiation conditions GB/T 17680.10-2003 Criteria for emergency planning and preparedness for nuclear power plants--Criteria for emergency radiological field monitoring,sampling and analysis conducted by nuclear power plant operating organizations GB/T 10257-2001 Quality inspection rule for nuclear instruments and nuclear radiation detectors GB/T 12162.1-2000 X and gamma reference radiation for calibrating dose meters and doserate meters and for determining their response as a function of photon energy--Part 1:Radiation characteristics and production methods GB/T 12128.2-1999 Reference sources for the calibration of surface contamination monitors--Part 2:Electrons of energy less than 0.15MeV and photons of energy less than 1.5MeV
Transparency note: The application summary and key sentences on this page were automatically generated by AI from the standard's original text. This content has not been human-verified and should not be used for compliance or regulatory purposes. Always refer to the official standard document from the issuing authority.