GB/T 7165.1-2005

Active

Equipment for continuous monitoring of radioactivity in gaseous effluents Part1:General requirements

气态排出流(放射性)活度连续监测设备 第一部分:一般要求

Standard Type
GBT
ICS
17.240
CCS
F85
Status
Active
Issue Date
2005-05-18
Implementation
2005-12-01
Centralized Committee
国家标准委
Issuing Authority
国家标准委

Application Summary AI generated

This standard specifies general requirements for equipment designed to continuously monitor the radioactivity of gaseous effluents released from nuclear facilities. It is applied in industries such as nuclear power plants, fuel reprocessing plants, and research reactors to ensure compliance with radiation safety regulations. The standard covers performance criteria, testing methods, and design features for monitoring systems used in environmental protection and occupational safety contexts.

Related Standards

GB/T 12162.2-2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy--Part 2:Dosimetry for radiation protection over the energy ranges 8keV to 1.3 MeV and 4MeV to 9MeV GB/T 12162.3-2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy--Part 3:Calibration of area and personal dosemeters and the measurement of their response as a function of en GB/Z 28820.4-2022 Long-term radiation ageing in polymers—Part 4: Effects of different temperatures and dose rates under radiation conditions GB/T 17680.10-2003 Criteria for emergency planning and preparedness for nuclear power plants--Criteria for emergency radiological field monitoring,sampling and analysis conducted by nuclear power plant operating organizations GB/T 10257-2001 Quality inspection rule for nuclear instruments and nuclear radiation detectors GB/T 12162.1-2000 X and gamma reference radiation for calibrating dose meters and doserate meters and for determining their response as a function of photon energy--Part 1:Radiation characteristics and production methods GB/T 12128.2-1999 Reference sources for the calibration of surface contamination monitors--Part 2:Electrons of energy less than 0.15MeV and photons of energy less than 1.5MeV GB/T 12164-1999 Reference beta radiations for calibrating dosemeters and doseratemeters and for determiningtheir response as a function of beta radiation energy
Transparency note: The application summary and key sentences on this page were automatically generated by AI from the standard's original text. This content has not been human-verified and should not be used for compliance or regulatory purposes. Always refer to the official standard document from the issuing authority.