GB/T 16639-2008

Active

Standard method for use of an alanine - EPR dosimetry system

使用丙氨酸-EPR剂量测量系统的标准方法

Standard Type
GBT
ICS
17.240
CCS
A58
Status
Active
Issue Date
2008-09-19
Implementation
2009-08-01
Centralized Committee
国家标准委
Issuing Authority
中华人民共和国国家质量监督检验检疫总局、中国国家标准化管理委员会

Application Summary AI generated

This standard specifies the procedures for using an alanine-electron paramagnetic resonance (EPR) dosimetry system to measure absorbed doses of ionizing radiation. It is applied in industrial radiation processing, such as food irradiation and medical device sterilization, as well as in radiation therapy and research laboratories for dose calibration and quality assurance. The standard ensures consistent and traceable dose measurements across these high-dose applications.

Related Standards

GB/T 12162.2-2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy--Part 2:Dosimetry for radiation protection over the energy ranges 8keV to 1.3 MeV and 4MeV to 9MeV GB/T 12162.3-2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy--Part 3:Calibration of area and personal dosemeters and the measurement of their response as a function of en GB/T 7165.1-2005 Equipment for continuous monitoring of radioactivity in gaseous effluents Part1:General requirements GB/Z 28820.4-2022 Long-term radiation ageing in polymers—Part 4: Effects of different temperatures and dose rates under radiation conditions GB/T 17680.10-2003 Criteria for emergency planning and preparedness for nuclear power plants--Criteria for emergency radiological field monitoring,sampling and analysis conducted by nuclear power plant operating organizations GB/T 10257-2001 Quality inspection rule for nuclear instruments and nuclear radiation detectors GB/T 12162.1-2000 X and gamma reference radiation for calibrating dose meters and doserate meters and for determining their response as a function of photon energy--Part 1:Radiation characteristics and production methods GB/T 12128.2-1999 Reference sources for the calibration of surface contamination monitors--Part 2:Electrons of energy less than 0.15MeV and photons of energy less than 1.5MeV
Transparency note: The application summary and key sentences on this page were automatically generated by AI from the standard's original text. This content has not been human-verified and should not be used for compliance or regulatory purposes. Always refer to the official standard document from the issuing authority.