GB/T 16510-2008
ActiveThe requirements for the competence of a radiation processing dosimetry calibration laboratory
辐射加工剂量学校准实验室的能力要求
Application Summary AI generated
This standard specifies the competence requirements for laboratories that calibrate dosimeters used in radiation processing, such as food irradiation, medical device sterilization, and polymer modification. It covers personnel qualifications, equipment traceability, measurement uncertainty, and quality management procedures specific to high-dose radiation environments. The standard is applied by calibration laboratories to ensure accurate dose measurement and compliance with international metrology practices for industrial radiation processing.
Related Standards
GB/T 12162.2-2004
X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy--Part 2:Dosimetry for radiation protection over the energy ranges 8keV to 1.3 MeV and 4MeV to 9MeV
GB/T 12162.3-2004
X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy--Part 3:Calibration of area and personal dosemeters and the measurement of their response as a function of en
GB/T 7165.1-2005
Equipment for continuous monitoring of radioactivity in gaseous effluents Part1:General requirements
GB/Z 28820.4-2022
Long-term radiation ageing in polymers—Part 4: Effects of different temperatures and dose rates under radiation conditions
GB/T 17680.10-2003
Criteria for emergency planning and preparedness for nuclear power plants--Criteria for emergency radiological field monitoring,sampling and analysis conducted by nuclear power plant operating organizations
GB/T 10257-2001
Quality inspection rule for nuclear instruments and nuclear radiation detectors
GB/T 12162.1-2000
X and gamma reference radiation for calibrating dose meters and doserate meters and for determining their response as a function of photon energy--Part 1:Radiation characteristics and production methods
GB/T 12128.2-1999
Reference sources for the calibration of surface contamination monitors--Part 2:Electrons of energy less than 0.15MeV and photons of energy less than 1.5MeV
Transparency note: The application summary and key sentences on this page were automatically generated by AI from the standard's original text. This content has not been human-verified and should not be used for compliance or regulatory purposes. Always refer to the official standard document from the issuing authority.