GB/T 14055.2-2012
ActiveReference neutron radiations - Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field
中子参考辐射 第2部分:与表征辐射场基本量相关的辐射防护仪表校准基础
Application Summary AI generated
GB/T 14055.2-2012 specifies the calibration fundamentals for radiation protection instruments used to measure neutron radiation, focusing on the basic quantities that characterize the radiation field. It is applied in metrology laboratories and nuclear facilities to ensure accurate calibration of neutron dosimeters and survey meters against reference neutron radiations. This standard is essential for maintaining consistency in radiation protection measurements across industries such as nuclear power, healthcare, and research.
Related Standards
GB/T 12162.2-2004
X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy--Part 2:Dosimetry for radiation protection over the energy ranges 8keV to 1.3 MeV and 4MeV to 9MeV
GB/T 12162.3-2004
X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy--Part 3:Calibration of area and personal dosemeters and the measurement of their response as a function of en
GB/T 7165.1-2005
Equipment for continuous monitoring of radioactivity in gaseous effluents Part1:General requirements
GB/Z 28820.4-2022
Long-term radiation ageing in polymers—Part 4: Effects of different temperatures and dose rates under radiation conditions
GB/T 17680.10-2003
Criteria for emergency planning and preparedness for nuclear power plants--Criteria for emergency radiological field monitoring,sampling and analysis conducted by nuclear power plant operating organizations
GB/T 10257-2001
Quality inspection rule for nuclear instruments and nuclear radiation detectors
GB/T 12162.1-2000
X and gamma reference radiation for calibrating dose meters and doserate meters and for determining their response as a function of photon energy--Part 1:Radiation characteristics and production methods
GB/T 12128.2-1999
Reference sources for the calibration of surface contamination monitors--Part 2:Electrons of energy less than 0.15MeV and photons of energy less than 1.5MeV
Transparency note: The application summary and key sentences on this page were automatically generated by AI from the standard's original text. This content has not been human-verified and should not be used for compliance or regulatory purposes. Always refer to the official standard document from the issuing authority.