GB/T 14055.1-2008

Active

Reference neutron radiations - Part 1: Characteristics and methods of production

中子参考辐射 第1部分:辐射特性和产生方法

Standard Type
GBT
ICS
17.240
CCS
F84
Status
Active
Issue Date
2008-07-18
Implementation
2009-04-01
Centralized Committee
国家标准委
Issuing Authority
中华人民共和国国家质量监督检验检疫总局、中国国家标准化管理委员会

Application Summary AI generated

This standard specifies the characteristics and production methods for reference neutron radiation fields used in the calibration of neutron measuring instruments and dosimeters. It is applied in metrology laboratories and radiation protection facilities to ensure consistent and traceable neutron radiation for testing and calibration purposes. The standard covers neutron energies from thermal to 20 MeV, supporting applications in nuclear power, radiation therapy, and workplace safety monitoring.

Related Standards

GB/T 12162.2-2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy--Part 2:Dosimetry for radiation protection over the energy ranges 8keV to 1.3 MeV and 4MeV to 9MeV GB/T 12162.3-2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy--Part 3:Calibration of area and personal dosemeters and the measurement of their response as a function of en GB/T 7165.1-2005 Equipment for continuous monitoring of radioactivity in gaseous effluents Part1:General requirements GB/Z 28820.4-2022 Long-term radiation ageing in polymers—Part 4: Effects of different temperatures and dose rates under radiation conditions GB/T 17680.10-2003 Criteria for emergency planning and preparedness for nuclear power plants--Criteria for emergency radiological field monitoring,sampling and analysis conducted by nuclear power plant operating organizations GB/T 10257-2001 Quality inspection rule for nuclear instruments and nuclear radiation detectors GB/T 12162.1-2000 X and gamma reference radiation for calibrating dose meters and doserate meters and for determining their response as a function of photon energy--Part 1:Radiation characteristics and production methods GB/T 12128.2-1999 Reference sources for the calibration of surface contamination monitors--Part 2:Electrons of energy less than 0.15MeV and photons of energy less than 1.5MeV
Transparency note: The application summary and key sentences on this page were automatically generated by AI from the standard's original text. This content has not been human-verified and should not be used for compliance or regulatory purposes. Always refer to the official standard document from the issuing authority.