QB/T 1078-2004
AbolishedDiscontinuous totalizing automatic weighing instruments (totalizing hopper weighers)
非连续累计自动衡器 (累计料斗秤)
Catalogue
前言 → 1 范围 → 2 规范性引用文件 → 3 术语 → 4 分类 → 5 要求 → 6 试验方法 → 7 计量控制 → 8 标志、包装、运输、贮存 → 附录A Foreword → 1 Scope → 2 Normative References → 3 Terms → 4 Classification → 5 Requirements → 6 Test Methods → 7 Metrological Control → 8 Marking, Packaging, Transport, Storage → Annex A
Scope
This standard specifies the requirements, test methods, metrological control, and marking, packaging, transport, and storage of discontinuous totalizing automatic weighing instruments (totalizing hopper weighers) (hereinafter referred to as instruments). This standard applies to instruments with a hopper-type load receptor, which divide a batch of bulk material into discrete loads, sequentially weigh each discrete load, totalize the weighing results, and discharge the discrete loads.
本标准规定了非连续累计自动衡器(累计料斗秤)(以下简称衡器)的要求、试验方法、计量控制、和标志、包装、运输、贮存。本标准适用于具有料斗式承载器,通过把一批散料分成不连续的载荷,依次称量每份不连续载荷的质量,累计称量结果,并将不连续载荷卸出的衡器。
Normative References
Keywords
Application Summary AI generated
This standard is used by scale manufacturers, metrology verification agencies, and quality inspection departments. They rely on it to design, produce, and verify discontinuous totalizing automatic weighing instruments (totalizing hopper weighers), ensuring accuracy and reliability in bulk material weighing. It is crucial for fair trade settlement and improving industrial production efficiency.
该标准由衡器制造商、计量检定机构和相关质检部门使用。他们依据此标准设计、生产和检验非连续累计自动衡器(累计料斗秤),确保其在散料称量过程中的准确性和可靠性。该标准对于保障贸易结算公平、提高工业生产效率具有重要意义。
AI Summary AI generated
This standard QB/T 1078-2004 replaces QB/T 1078-1991 and modifies OIML R 107-1997. It specifies technical requirements, test methods, metrological control, and marking/packaging for discontinuous totalizing automatic weighing instruments (totalizing hopper weighers). Instruments are classified into four accuracy classes: 0.2, 0.5, 1, and 2, with corresponding maximum permissible errors. The standard details test procedures including material tests, simulation tests, and influence factor tests, and adds requirements for packaging, transport, storage, and modifications to EMC tests.
本标准QB/T 1078-2004替代了QB/T 1078-1991,修改采用OIML R 107-1997国际建议。标准规定了非连续累计自动衡器(累计料斗秤)的技术要求、试验方法、计量控制及标志包装等。衡器分为0.2、0.5、1、2四个准确度等级,并给出了相应的最大允许误差。标准详细描述了物料试验、模拟试验、影响因子试验等测试程序,并增加了包装运输储存要求及电磁兼容试验的修改。
Key Sentences extracted from text
本标准规定了非连续累计自动衡器(累计料斗秤)(以下简称衡器)的要求、试验方法、计量控制、和标志、包装、运输、贮存。
本标准适用于具有料斗式承载器,通过把一批散料分成不连续的载荷,依次称量每份不连续载荷的质量,累计称量结果,并将不连续载荷卸出的衡器。
衡器分为四个准确度等级: 0.2, 0.5, 1, 2。
每个准确度等级的最大允许误差应为表1中的对应值,其值应化整到最接近的累计分度值上。
本标准修改采用国际法制计量组织107号国际建议(OIML R 107-1997)《非连续累计自动衡器(累计料斗秤)》。
This standard specifies the requirements, test methods, metrological control, and marking, packaging, transport, and storage of discontinuous totalizing automatic weighing instruments (totalizing hopper weighers).
This standard applies to instruments with a hopper-type load receptor, which divide a batch of bulk material into discrete loads, sequentially weigh each discrete load, totalize the weighing results, and discharge the discrete loads.
Instruments are divided into four accuracy classes: 0.2, 0.5, 1, 2.
The maximum permissible error for each accuracy class shall be the corresponding value in Table 1, and the value shall be rounded to the nearest totalization scale interval.
This standard modifies the International Recommendation OIML R 107-1997 of the International Organization of Legal Metrology, 'Discontinuous totalizing automatic weighing instruments (totalizing hopper weighers)'.
Standard Timeline
Changes from replaced version:
- 标准修改采用国际法制计量组织107号国际建议(OIML R 107-1997)
- 标准名称根据国际建议更改为《非连续累计自动衡器(累计料斗秤)》,使其内容与名称相符
- 标准根据国际建议的内容,对技术要求、试验方法进行了更加具体和详尽的叙述
- 增加了包装、运输和储存的要求
- 增加了分离检定法和集成检定法物料试验误差的计算公式
- 电快速瞬变脉冲群抗扰度试验对于电源输入输出端口的脉冲峰值由0.5 kV改为1 kV
- 电磁敏感性试验无线电频率电磁场由26 MHz-1000 MHz改为80 MHz-1000 MHz
- The standard modifies the International Recommendation OIML R 107-1997
- The standard name is changed to 'Discontinuous totalizing automatic weighing instruments (totalizing hopper weighers)' to align content with the name
- The standard provides more specific and detailed descriptions of technical requirements and test methods based on the international recommendation
- Added requirements for packaging, transport, and storage
- Added calculation formulas for material test errors in the separate verification method and integrated verification method
- The pulse peak value for power input/output ports in the electrical fast transient/burst immunity test is changed from 0.5 kV to 1 kV
- The radio frequency electromagnetic field for electromagnetic susceptibility test is changed from 26 MHz-1000 MHz to 80 MHz-1000 MHz