JB/T 11648-2013

Active

Coal-fired flue gas wet desulfurization equipment using calcium carbide slag

燃煤烟气电石渣湿法脱硫设备

Standard Type
JB
ICS
N/A
CCS
N/A
Status
Active
Issue Date
2013-11-25
Implementation
2014-03-01
Centralized Committee
机械工业环境保护机械标准化技术委员会 (CMIF/TC7) / Machinery Industry Environmental Protection Machinery Standardization Technical Committee (CMIF/TC7)
Issuing Authority
机械工业环境保护机械标准化技术委员会 (CMIF/TC7) / Machinery Industry Environmental Protection Machinery Standardization Technical Committee (CMIF/TC7)

Catalogue

前言 → 1 范围 → 2 规范性引用文件 → 3 术语和定义 → 4 要求 → 5 调试、启动及验收 → 6 运行与维护 → 标牌、标志、包装、运输和贮存 → 附录 A (资料性附录) 电石渣浆液制备系统流程图 Foreword → 1 Scope → 2 Normative References → 3 Terms and Definitions → 4 Requirements → 5 Commissioning, Startup and Acceptance → 6 Operation and Maintenance → Nameplates, Marks, Packaging, Transport and Storage → Annex A (Informative) Flowchart of Carbide Slurry Preparation System

Scope

This standard specifies the terms and definitions, requirements, commissioning, startup and acceptance, operation and maintenance, nameplates, marks, packaging, transport and storage of coal-fired flue gas calcium carbide slag-gypsum wet desulfurization equipment. This standard applies to wet desulfurization projects for new, expanded or retrofitted coal-fired thermal power generating units with a unit capacity of 1000 MW and below, where the absorption tower is a spray tower, liquid column tower or other empty tower structure; it does not apply to packed towers, bubbling towers, grid towers, or projects where calcium carbide slag is directly fed into a circulating fluidized bed for in-furnace desulfurization.

本标准规定了燃煤烟气电石渣-石膏湿法脱硫设备的术语和定义,要求,调试、启动及验收,运行与维护,标牌,标志,包装,运输和贮存。本标准适用于机组容量 1000 MW 及以下新建,扩建或改建的燃煤火力发电机组的湿法脱硫工程,吸收塔为喷淋塔,液柱塔等空塔结构; 不适用于填料塔,鼓泡塔,格栅塔及用电石渣直接进入循环流化床进行炉内脱硫的工程。

Normative References

GB/T 19229.1-2008 GB 50015 GB 50016 GB 50058 GB 50116 GB 50160 DL/T 998 DL/T 5136 DL/T 5153 DL/T 5196-2004 DL/T 5403 DL/T 5437

Keywords

燃煤烟气 (coal-fired flue gas) 电石渣 (calcium carbide slag) 湿法脱硫 (wet desulfurization) 脱硫设备 (desulfurization equipment) 火力发电 (thermal power generation) 喷淋塔 (spray tower) 液柱塔 (liquid column tower)

Application Summary AI generated

This standard is used by engineers and operators in thermal power plants for designing, installing, and maintaining wet desulfurization equipment that utilizes calcium carbide slag as a desulfurizing agent. It ensures reliable and efficient operation of spray towers and liquid column towers, while excluding unsuitable tower types like packed or bubbling towers. Compliance with this standard is critical for meeting environmental emission regulations and ensuring safe plant operation.

该标准主要供火力发电厂的设计、建设和运维人员使用,用于指导采用电石渣作为脱硫剂的湿法脱硫设备选型、安装和运行。它确保了脱硫系统在喷淋塔或液柱塔等空塔结构中的可靠性和效率,同时排除了填料塔等不适用场景,对环保达标和安全生产至关重要。

AI Summary AI generated

This standard specifies technical requirements for coal-fired flue gas wet desulfurization equipment using calcium carbide slag, covering terms, design, commissioning, operation, and maintenance. It applies to spray towers or liquid column towers in thermal power units up to 1000 MW, excluding packed towers or in-furnace desulfurization. The standard defines the properties of calcium carbide slag as a byproduct and references multiple related codes, aiming to guide equipment selection and safe operation to ensure desulfurization efficiency and environmental compliance.

本标准规定了燃煤烟气电石渣-石膏湿法脱硫设备的技术要求,涵盖术语、设计、调试、运行及维护。适用于1000 MW及以下火电机组的喷淋塔或液柱塔等空塔结构脱硫工程,不适用于填料塔或炉内脱硫。标准明确了电石渣作为副产物的特性,并引用多项相关规范,旨在指导设备选型与安全运行,确保脱硫效率和环保达标。

Key Sentences extracted from text

1.

本标准规定了燃煤烟气电石渣-石膏湿法脱硫设备的术语和定义,要求,调试、启动及验收,运行与维护,标牌,标志,包装,运输和贮存。

2.

本标准适用于机组容量 1000 MW 及以下新建,扩建或改建的燃煤火力发电机组的湿法脱硫工程,吸收塔为喷淋塔,液柱塔等空塔结构;

3.

不适用于填料塔,鼓泡塔,格栅塔及用电石渣直接进入循环流化床进行炉内脱硫的工程。

4.

电石渣 (CaC2) 生产乙炔气体所产生的副产物,主要成分为 Ca(OH)2。

5.

在粉碎后的电石中喷入水制备乙炔所产生的副产物,其物料中含水量不大于 8% (质量分数),粒径不大于 270 μm,粉状,可采用自卸式罐车或气力输送到脱硫区域。

7.

This standard specifies the terms and definitions, requirements, commissioning, startup and acceptance, operation and maintenance, nameplates, marks, packaging, transport and storage of coal-fired flue gas calcium carbide slag-gypsum wet desulfurization equipment.

8.

This standard applies to wet desulfurization projects for new, expanded or retrofitted coal-fired thermal power generating units with a unit capacity of 1000 MW and below, where the absorption tower is a spray tower, liquid column tower or other empty tower structure;

9.

It does not apply to packed towers, bubbling towers, grid towers, or projects where calcium carbide slag is directly fed into a circulating fluidized bed for in-furnace desulfurization.

10.

Calcium carbide slag is a byproduct from the production of acetylene gas from calcium carbide (CaC2), with the main component being Ca(OH)2.

11.

The byproduct from spraying water into crushed calcium carbide to produce acetylene has a moisture content not greater than 8% (mass fraction), a particle size not greater than 270 μm, is powdery, and can be transported to the desulfurization area by self-unloading tanker or pneumatic conveying.

Transparency note: The application summary and key sentences on this page were automatically generated by AI from the standard's original text. This content has not been human-verified and should not be used for compliance or regulatory purposes. Always refer to the official standard document from the issuing authority.