GB/T 38588-2020
ActiveIn-situ measurements of heat loss of insulating pipes for urban heat-supplying
城镇供热保温管网系统散热损失现场检测方法
Application Summary AI generated
This standard specifies the on-site testing methods for measuring heat loss in insulating pipes used in urban centralized heating networks. It is applied during the operation or acceptance inspection of district heating systems to evaluate the thermal insulation performance of buried or above-ground pipelines. The standard provides procedures for engineers to quantify energy efficiency and identify excessive heat loss in real-world conditions.
Related Standards
GB/T 19249-2003
Reverse osmosis water treatment equipment
GB/T 16895.3-2004
Electrical installations of buildings--Part 5-54:Selection and erection of electrical equipment--Earthing arrangements,protective conductors and protective bonding conductors
GB/T 7725-2004
Room air conditioners
GB/T 16895.22-2004
Electrical instal lations of buildings--Part 5-53:Selection and erection of electrical equipment isolation,switching and control--Section 534:Devices for protection against overvoltages
GB/Z 28598-2012
Study of the use of lifts for evacuation during an emergency
GB/Z 28597-2012
Lifts and escalators subject to seismic conditions - Compilation report
GB/Z 31822-2015
Study report on the safety requirements of public service escalators and moving walks
GB/Z 35850.3-2021
Programmable electronic systems in safety-related applications for lifts (elevators), escalators and moving walks—Part 3: Life cycle guideline for programmable electronic systems related to PESSRAL and PESSRAE
Transparency note: The application summary and key sentences on this page were automatically generated by AI from the standard's original text. This content has not been human-verified and should not be used for compliance or regulatory purposes. Always refer to the official standard document from the issuing authority.