GB/T 14634.4-2002
AbolishedTest methods of rare earth three-band phosphors for fluorescent lamps--Determination of particle size distribution by electric sensing zone technique
灯用稀土三基色荧光粉试验方法 电传感法粒度分布测定
Application Summary AI generated
This standard specifies the method for determining the particle size distribution of rare earth three-band phosphors used in fluorescent lamps, employing the electric sensing zone technique (e.g., Coulter principle). It is applied in the manufacturing and quality control of phosphor powders for energy-saving fluorescent lamps, ensuring consistent particle size for optimal luminescence and coating uniformity. The test is critical for metallurgical and lighting industries to verify powder specifications during production and incoming material inspection.
Related Standards
GB/T 5153-2003
Designation and composition of wrought magnesium and magnesium alloys
GB/T 12690.13-2003
Chemical analysis methods for non-rareearth impurities of rare earth metals and their oxides--Determination of molybdenum and tungsten content--Induct-ively coupled plasma atomic emission spectrographic method and inductively coupled plasma mass spectrum
GB/T 12690.4-2003
Chemical analysis methods for non-rare earth impurities ofrare earth metals and their oxides--Determination of oxygen and nitrogen content--Impulse-infrared and impulse-thermal conductance absorption method
GB/T 12690.11-2003
Chemical analysis methods for non-rare earth impurities of rare earth metals and their oxides--Determination of magnesium content--Flame atomic absorptionspectrometric method
GB/T 12690.10-2003
Chemical analysis methods for non-rare earth impurities of rare earth metals and their oxides--Determination of phosphorus content by molybdenum blue spectrophotometric method
GB/T 12690.12-2003
Chemical analysis methods for non-rare earth impurities of rare earth metals and their oxides--Determination of thorium content--Arsenazo III spectrophotometric method and inductively coupled plasma mass spectrum method
GB/T 12690.5-2003
Chemical analysis methods for non-rare earth impurities of rare earth metals and their oxides--Determination of Al、Cr、Mn、Fe、Co、Ni、Cu、Zn、Pb content by inductively coupled plasma atomic emission spectrographic method--Determination of Co、Mn、Pb、N
GB/T 12690.6-2003
Chemical analysis methods for non-rare earth impurities of rare earth metals and their oxides--Determination of iron content--Kalium thiocyanate,1,10-phenanthroline spectrophotometric method
Transparency note: The application summary and key sentences on this page were automatically generated by AI from the standard's original text. This content has not been human-verified and should not be used for compliance or regulatory purposes. Always refer to the official standard document from the issuing authority.